Technical Resources for Architectural Membrane Projects

Find architectural membrane technical data by grade, surface and document purpose. Request a tensile membrane datasheet, supporting test evidence and fabrication information for PVC-coated polyester fabric. Check material identity, revision and application scope before using a file in your project submittal.

White curved membrane roof shown in DERFLEX architectural material imagery
Architectural application image from the DERFLEX website; shown for material context, without a project supply claim.

The right file starts with identity

Grade. Finish. Revision. Scope.

Carry the same identifiers from the first inquiry through sample review, material approval and purchase order.

  • Identify the proposed grade and both fabric faces.
  • Request the exact document type needed.
  • Retain the issued version with the project record.
Focus PVC-coated polyester architectural membranesFor Design, fabrication and procurement teams

Find the material reference

Grade and Document Index

The following codes are listed on DERFLEX’s existing tensile membrane fabric page. They are useful inquiry references, not a structural grading system or an approved document list. Selecting a row does not confirm that a particular report exists or that the material is accepted for your project.

4 document request entries

Grade and document request index — current issue to be confirmed
GradeSurface / color scopeDocument typeRevision / issue datePurpose and applicabilityRequest
DG1330Public catalogue referenceDouble-side lacquered; color to be identifiedTDSRequest availabilityNot publicly listedAsk for current revision and issue dateMaterial identification and directional property summaryAsk for documents
DG1330Public catalogue referenceExact color and finish to be identifiedTest / classification evidenceRequest availabilityNot publicly listedAsk for current revision and issue dateReport scope for the proposed material and intended useAsk for documents
DG1122DPublic catalogue referenceKnife-coated construction; finish to be identifiedTDSRequest availabilityNot publicly listedAsk for current revision and issue dateConfirm suitability and grade-specific material dataAsk for documents
DG1122Public catalogue referenceColor and finish to be identifiedTDSRequest availabilityNot publicly listedAsk for current revision and issue dateConfirm architectural use and required documentationAsk for documents

Scroll horizontally on smaller screens. “Not publicly listed” describes the public file metadata, not a claimed document revision.

Working from a sample or an older quotation? Include its code, date, color and face photographs. Ask DERFLEX to reconcile the identity before requesting a replacement file. Do not substitute a similar-looking grade code.

Review the evidence

TDS and Test Reports

A PVC membrane TDS is the material summary; the underlying test report records how a particular specimen was evaluated. Keep these roles distinct. A tender may need both, as well as a classification document or a project-specific trial record.

Choose the evidence that answers the project question
EvidenceCheck before using itWhat it does not establish
Technical data sheetGrade, construction, color or finish scope, directional values, methods, units, value basis and revision.Approval of the structure or confirmation that a different variant has identical properties.
Mechanical test reportSpecimen identity, warp / weft direction, conditioning, method, result basis and report identifier.Project design resistance, prestress or compensation without the responsible engineer’s evaluation.
Fire test / classification documentNamed material, measured or classified result, issuer, issue information and end-use or mounting scope.Equivalence between different national classes or approval of the complete roof assembly.
Optical / weathering evidenceColor, surface, specimen condition, measurement or exposure method and properties assessed.A fixed indoor temperature saving or a conversion from laboratory hours to outdoor service years.

On smaller screens, scroll the table horizontally to read every field.

Read the identity block first

Match the grade, finish and color to the proposed material. Next check the issue details, test reference and acceptance basis. If the document and sample cannot be reconciled, resolve that mismatch before comparing numerical results.

Record whether a property is a typical result, a specified minimum or a separately agreed tolerance. Preserve the original units and directional labels when transferring information into a specification.

Need a review copy?

Ask for the current issued TDS and permission to circulate it within the project team. State whether you need a public reference, tender submittal or restricted technical review copy.

No public TDS PDF is linked here. Use the document request route to confirm available files and their permitted use.

Connect material and process

Fabrication Information

Fabrication information must follow the actual coating and surface variant. The product name “PVDF” alone does not define a welding procedure. Clarify the exterior face, the reverse face, any surface preparation and the process to be qualified before planning production.

Material and face identification

Record the supplied grade, batch, roll label, color and face orientation. Keep the sample identifier beside the document reference so a change in finish is visible to the fabricator.

Welding and seam trials

Request available processing guidance for the proposed variant. Record equipment, preparation, seam geometry, loading direction and trial conditions; agree acceptance with the project reviewer.

Biaxial and patterning information

State the data format and test conditions the designer needs. Check the available report’s grade and loading history. The responsible designer evaluates its use for stiffness, patterning and compensation.

Production and delivery records

Agree roll identification, sample retention, batch allocation and inspection records before supply. A project file should make it possible to connect the approved material identity to the delivered rolls.

Review the PVDF lacquered PVC membrane product information and the PVC and PVDF surface comparison when defining the finish to be submitted. Use the membrane selection guide to coordinate the broader material review.

Keep the issued record

Revision and Scope Control

Build the register around individual issued documents. A folder of unnamed PDFs is difficult to review and easy to reuse out of context. Each project entry should connect the file to its exact material and approval purpose.

Minimum fields for a controlled project document register
Register fieldRecord to retainReview action
Material identityGrade, color code, surface system and sample or batch reference.Reconcile with the quotation, sample and order description.
Document identityDocument title, type, issuer, number, revision and issue date.Keep the original file and the source of issue.
Applicable scopeProject, intended use, specimen, method and any stated limitations.Have the responsible reviewer confirm relevance.
Issue and decisionReceived date, document contact, status, reviewer and decision reference.Separate received, under review and approved records.
SupersessionReplacement issue, change summary and affected project records.Retain the previous issue in the audit trail; prevent accidental reuse.

On smaller screens, scroll the table horizontally to read every field.

If a document changes, request a description of the affected material or test information. Have the relevant reviewer decide whether the approved sample, seam trial, material schedule or purchase order needs revision. Keep the decision alongside the superseded issue.

Prepare your request

Request a Controlled Document

Send one coordinated request with enough detail to identify the proposed supply. If a grade has not been selected, start with the project application and engineer’s requirements rather than guessing a catalogue code.

Include these details in your request

  • Project name, country and roof or canopy use.
  • Proposed grade, quotation or sample reference.
  • Color, surface finish and face orientation.
  • Required document types and intended review purpose.
  • Required methods, report scope and language.
  • Receiving contact, reviewer and requested issue date.

Ask who will issue the files, which revision is current, and whether your required evidence is available for the exact variant. Availability and testing scope are confirmed for the individual request.

Before you order

Reconcile the approved material schedule with the quotation and purchase order. Check that the order names the same grade, finish, color, roll or panel scope and required evidence. Resolve missing or superseded documents before using them as the basis for approval.

Common project questions

Architectural Membrane Documentation FAQ

What should an architectural membrane technical data sheet identify?

A useful TDS identifies the grade, reinforcement, coating, surface finish, color or color scope, units, test methods, directional properties and issue information. It should state whether values are typical, minimum or subject to agreed tolerances. A web product description is a starting point for inquiry, not a controlled project submittal.

Is a PVC membrane TDS the same as a test report?

No. A TDS summarizes the material. A test report records the tested specimen, method, conditions and results. A classification document may define additional application limits. Request each document needed by the project and check that its material identity matches the proposed supply.

Can I use another color or surface finish under the same report?

Only when the document explicitly covers that variant or the responsible issuer confirms its scope. Color, coating, thickness, mass and surface treatment can affect the relevance of a report. Do not extend a result to a different variant simply because the base product name looks similar.

Where can I obtain the current tensile membrane datasheet?

Send the grade code, color, finish, project country, intended use and required document list through the DERFLEX inquiry page. Ask for the current issued revision and its availability. This page provides a request route; it does not offer unverified PDF downloads or promise every test for every grade.

Does a catalogue fire label approve the building system?

No. A catalogue label is not a substitute for the actual report and its scope. The project reviewer must assess the stated material, mounting or end-use conditions and the applicable local requirements. Material documentation does not by itself approve the roof assembly or whole structure.

What should I check when a document is revised?

Compare the grade identity, color and finish, changed properties, methods, intended scope and issue status. Record the new revision in the project register and have the appropriate reviewer assess any effect on material approval, fabrication trials, ordering or replacement stock.